Provedení:Rack mounted 19"; Funkce:L2+L4, L3; Technologie:Gigabit Ethernet + 10 GbE porty; Počet portů LAN:24; Počet portů LAN:24; Podporované standardy PoE:802.3at; Počet PoE Out portů:24; Počet PoE Out portů:24; Počet SFP portů:8; Počet SFP portů:8; Počet SFP+ portů:4; Počet SFP+ portů:4; Počet portů SFP28:0; Počet portů SFP28:0; Počet portů QSFP28:0

Vaše cena:
Dostupnost: Obvykle 28 dnů
Kód:
713988
P/N:
R9L63AR
Záruka:
99 Doživotní
Výrobce:
Hewlett Packard Enterprise
EAN:

Podrobnosti

HPE FlexNetwork 5140 24G PoE+ 4SFP+ HI Switch R9L63AR RENEW

Generic

IEC 61000-4-1:2006;

IEC 61000-4-2:Ed2 2008;

IEC 61000-4-3:2020;

IEC 61000-4-3:2010;

IEC 61000-4-4:2004;

IEC 61000-4-4:2011;

IEC 61000-4-4:Ed3.0 2012;

IEC 61000-4-5:2014;

IEC 61000-4-5:2017;

IEC 61000-4-6:2013;

IEC 61000-4-6:2013 COR1:2015;

IEC 61000-4-8:2009;

IEC 61000-4-11:2004;

IEC 61000-4-11:2017;

IEC 61000-4-11:2020

ESD

Air 8KV; Con 6KV; Criteria B

Inmunity

ETSI EN300 386 V1.6.1 (2012-09); ETSI EN 300 386 V2.1.1 (2016-07); EN 55035:2017; CISPR 35:2016;

Management

IMC-Intelligent Management Center; Smart MC, command-line interface; SNMP Manager

Services

Refer to the Hewlett Packard Enterprise website at: http://www.hpe.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local Hewlett Packard Enterprise sales office.

HPE FlexNetwork 5140 24G PoE+ 4SFP+ HI Switch (R9L63A)

I/O ports and slots

24 RJ-45 autosensing 10/100/1000 PoE+ ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T, IEEE 802.3at PoE+),

4 SFP+ 10GbE ports 1 port expansion module slot

Additional ports and slots

1 dual-personality (RJ-45 or mini-USB) serial console port

1 RJ-45 out-of-band management port

1 USB 2.0

Power supplies

2 power supply slots 1 minimum power supply required

Fan tray

Airflow direction is from side to back

Physical characteristics

Dimensions

17.32(w) x 18.11(d) x 1.71(h) in. (44.00 x 46.00 x 4.36 cm) (1U height)

Weight

≤9.2 kg

Memory and processor

2 GB SDRAM; Packet buffer size: 4 MB, 512 MB flash

Mounting and enclosure

Mounts in an EIA standard 19-inch telco rack or equipment cabinet (hardware included)

Performance

1000 Mb Latency

< 5 µs

10 Gbps Latency

< 3 µs

Throughput

180 Mpps

Routing/Switching capacity

288 Gbps

Routing table size

8K

MAC address table size

32K

Environment

Operating temperature

23°F to 113°F (-5°C to 45°C)

Operating relative humidity

5% to 95%, noncondensing

Non-operating/Storage temperature

-40°F to 158°F (-40°C to 70°C)

Non-operating/Storage relative humidity

5% to 95%, noncondensing

Acoustic

low speed fan: 57.2 dB, High speed fan: 68.9 dB. ISO 7779

Electrical characteristics

Frequency

50/60 Hz

Maximum heat dissipation

ranges from 105.7 BTU/hr to 3166 BTU/hr depending on power supply configuration

Current

20A

Voltage

100-240 VAC, rated (90-264 VAC, max)-48 to -60 VDC, rated (-36 to -72 VDC, max) (depending on power supply chosen)

Maximum power rating

928 W (dual AC)

Idle power

31 W (dual AC)

PoE power

720W (30W max PoE power per port)

Notes:

- Idle power is the actual power consumption of the device with no ports connected.

- Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated

- PoE+ power range is from 360W to 740W. PoE+ power is the power supplied by the internal power supplies. It is dependent on the type and quantity of power supplies. Device supports 1 or 2 internal modular power supplies.

Safety

UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part 2;IEC 60950-1; EN 60950-1; CAN/CSA-C22.2 No. 60950-1; FDA 21 CFR Subchapter J; RoHS Compliance; AS/NZS 60950-1; GB 4943; EAC (EurAsian Conformity Certification)

Emissions

ETSI EN300 386 V1.6.1 (2012-09); ETSI EN 300 386 V2.1.1 (2016-07); EN 55032:2015 CLASS A; CISPR 32:2015 CLASS A; AS/NZS CISPR 32:2015 CLASS A; EN 61000-3-2:2014; EN 61000-3-3:2013; FCC PART15 Subpart B CLASS A; ICES-003 Issue 7 CLASS A; ANSI C63.4-2014; VCCI-CISPR 32:2016 CLASS A

Generic

IEC 61000-4-1:2006;

IEC 61000-4-2:Ed2 2008;

IEC 61000-4-3:2020;

IEC 61000-4-3:2010;

IEC 61000-4-4:2004;

IEC 61000-4-4:2011;

IEC 61000-4-4:Ed3.0 2012;

IEC 61000-4-5:2014;

IEC 61000-4-5:2017;

IEC 61000-4-6:2013;

IEC 61000-4-6:2013 COR1:2015;

IEC 61000-4-8:2009;

IEC 61000-4-11:2004;

IEC 61000-4-11:2017;

IEC 61000-4-11:2020

ESD

Air 8KV; Con 6KV; Criteria B

Management

ETSI EN300 386 V1.6.1 (2012-09); ETSI EN 300 386 V2.1.1 (2016-07); EN 55035:2017; CISPR 35:2016;

Services

Refer to the Hewlett Packard Enterprise website at: http://www.hpe.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local Hewlett Packard Enterprise sales office.

Technické parametry